Nedap uPASS Reach readers use UHF RFID technology and are often used for long-range vehicle identification in parking garages.
Note: This reader requires external power. Current consumption: 1A @ 12VDC or 500mA @ 24VDC. For more information, refer to the uPASS Reach user guide.
Integrating uPASS Reach readers with Core Series hardware
Wiring uPASS Reach reader with Core Series hardware
Nedapp uPASS Reach | Openpath Core Series hardware |
---|---|
OUT2 (D0) | AUX1 (D0) |
OUT3 (D1) | AUX2 (D1) |
GND | GND |
Integrating uPASS Reach readers with first-generation hardware
Wiring uPASS Reach reader with first gen hardware
Nedapp uPASS Reach | Openpath first gen hardware |
---|---|
OUT2 (D0) | D0 |
OUT3 (D1) | D1 |
GND | GND |
Integrating uPASS Reach readers with Single Door Controller
Wiring uPASS Reach reader with Single Door Controller (SDC)
Nedapp uPASS Reach | Openpath SDC |
---|---|
OUT2 (D0) | D0 |
OUT3 (D1) | D1 |
GND | GND |
Setting up uPASS Reach reader in the Control Center
To configure Wiegand inputs on Core Series hardware:
Go to https://control.openpath.com/login and log in. To access the European Control Center, please go to https://control.eu.openpath.com/login.
Go to Devices > ACUs, then click on the ACU to edit it
Click on the Ports tab
Click Port next to the first input of the I/O pair with the uPASS Reach reader configured
Select Wiegand Device from the Input Type dropdown, then click Save
This will label the subsequent input as Wiegand Device (Extended) and disable it from editing. Inputs cannot be changed if they are already assigned to an entry.
Input settings in the Control Center
Once the Wiegand Device is configured on the ACU, it can be assigned to an entry.
Assigning a Wiegand Device to an entry
For more information on creating Entries, refer to the Openpath User Guide.
To add a uPASS Reach reader to an entry:
Go to https://control.openpath.com/login and log in. To access the European Control Center, please go to https://control.eu.openpath.com/login.
Go to Sites > Entries and click on an existing entry to edit or click the plus(+) on the top right to Create an Entry
Scroll down to Wiegand Device
From the Port dropdown, select the port for the uPASS Reach reader to which this entry is wired
From the Mode dropdown, select Input
Click Save
0 Comments