The current Openpath Jira and Confluence instances will be migrated to the MSI On-Premise solution from August 9th-11th, the current platform will be set to read-only and all future usage will be in the Avigilon Instance. Please ensure access to MSI Jira & MSI Confluence, both are accessible through OKTA. For additional information and details please refer to the Atlassian migration page

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 31 Next »

Note: This configuration requires the /wiki/spaces/EHC/pages/1607041051, which is included in the Premium Plan. To view more details about your plan, log into Avigilon Alta Access and go to Administration > Account.

Wire the button to the ACU:

  1. Wire the button to an available input on the ACU.

  2. Refer to your wired button’s manufacturer’s instructions.

Configuring the Input in Alta Access (Not Required for Auxiliary Input)

  1. Access Alta Access:

  2. Edit the ACU:

    • Navigate to Devices > ACUs.

    • Click on the ACU you want to edit.

  3. Configure the Port:

    • Go to the Ports tab.

    • Click on the port next to the input wired to the button (e.g., Contact4).

    • Select Generic Input from the Input Type dropdown, then click Save.

Creating a Lockdown Plan

  1. Refer to Instructions:

Creating Rules in the Rules Engine

  1. Access the Rules Engine:

    • Go to Configurations > Rules.

    • Click the plus (+) sign in the top right corner to create a new rule.

  2. Define the Rule:

    • Enter a name and description for the rule.

  3. Set the Trigger:

    • In the Trigger section:

      • From the Type dropdown, select Input.

      • From the Event dropdown, select Generic Input State Changed.

  4. Add Conditions:

    • In the Conditions section:

      • Click Add Condition.

        • From the Type dropdown, select ACU Port Filter.

        • From the ACU To Match dropdown, select the ACU with the wired button.

        • From the ACU Port To Match dropdown, select the button's Generic Input (e.g., Contact4).

      • Click Add Condition again.

        • From the Type dropdown, select Input State.

        • From the State to Match dropdown, select the appropriate state (based on how the button is wired).

          • For toggle switch buttons wired to NC, select high to trigger and low to revert.

          • For toggle switch buttons wired to NO, select low to trigger and high to revert.

  5. Define Actions:

    • In the Actions section:

      • From the Type dropdown, select Lockdown.

      • From the Lockdown Plan dropdown, select the plan you want the button to trigger.

      • From the Lockdown Action dropdown, select Trigger Lockdown.

    • Repeat steps 1-5. In step 5, under the Lockdown Action dropdown, select Revert Lockdown.

  6. Save the Rule:

    • Click Save.