Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

You can connect Allegion’s Schlage® Gateways and NDEB, LEB, and Control™ wireless locks to your Avigilon Alta system by using the ENGAGE app and the Open Admin Alta Access app.

Info

Note: Privacy Mode is supported for Allegion wireless lock integrations.

#FFBDAD
Info

Note: Supported features and limitations for Allegion Schlage wireless locks.

Panel
panelIconIdatlassian-info
panelIcon:info:
bgColor

Note: Please read /wiki/spaces/EHC/pages/1890287619

To enable this feature, refer to How to enable features in Avigilon Alta Access.

Requirements

Info

Note: The org’s Site site in the Alta Access system must have an address in order to get accurate timestamps on Allegion events. Go to Sites > Site > Edit Site and edit site to enter an address.

Overview of setup

Note: You must perform these steps in the specified order.

  1. Install Gateways and locks (refer to Allegion documentation)

    1. Schlage LE Lock Installation Guide

    2. Schlage NDE Lock Installation Guide

    3. Schlage Control Deadbolt Installation Guide

    4. Schlage Control Interconnected Installation Guide

    5. Engage Gateway Installation Guide

  2. Present Configuration Card to the lock

  3. Accept the invitation to Allegion Site

  4. Add the Gateway in the ENGAGE app

  5. Add the lock in the ENGAGE app

  6. Link the lock to the Gateway

  7. Sync gateways and locks to Avigilon Alta

  8. Update firmware on gateways and locks

  9. Adjust lock settings in Avigilon Alta Access

  10. Create an entry with the wireless lock

  11. How to add a Gateway from another Org

Anchor
present
present
Present Configuration Card to lock:

If you purchased locks outside of Avigilon Alta, and you’re using Openpath DESFire card credentials, present the appropriate Configuration Card to the lock within the first minute of powering on. A triple beep followed by a full reader reset indicates success.

Anchor
accept
accept
Alta Access (Formally Open Admin) Accept the invitation to the Allegion Site:

  1. Open the Open Admin Alta Access app first.

  2. Tap the name of the Org org to which you’ll provision these locks and gateways.

  3. Tap 3rd Party Devices.

...

  1. On the web page, accept Allegion’s terms and create an account using the email address associated with your Avigilon Alta account.

Anchor
addgateway
addgateway
(ENGAGE) Add the

...

gateway:

  1. Open the ENGAGE app and log in.

  2. Tap on the plus sign to add a device.

  3. Tap on Gateway.

  4. Tap the gateway’s serial number.

  5. Enter a name for the gateway.

  6. For Gateway gateway communication mode, tap IP.

  7. On IP Configuration, enable IP Behind Firewall and tap DHCP.

  8. On the IP Behind Firewall screen, enter the following:

    Code Block
    Server URL: https://ozone.prod.openpath.com 
    CA Server URL: http://ozone.prod.openpath.com/cert
Info

Note: These URLs must be entered correctly in order for the integration to work. If you entered them incorrectly during setup, you can edit them later by tapping on the Gateway > Settings > Host Configuration.

Anchor
addlock
addlock
(ENGAGE) Add the Lock:

  1. Tap on the plus sign to add a device.

  2. Tap on the model of lock you’re commissioning (Avigilon Alta supports LEB, NDEB, and Control locks).

  3. The app will ask if you want to use default settings — tap Yes (you can adjust lock configurations later in the Avigilon Alta Access).

  4. Tap the lock’s serial number.

  5. Follow the in-app instructions for connecting the lock.

  6. Enter a name for the lock.

  7. (NDEB and LEB only) On the Select the lock function page, select Storeroom.

...

8. Skip the Wi-Fi configuration step if able, since the lock will connect to the Internet via the Gatewaygateway. Some lock models might require that you specify a Wi-Fi configuration, in which case, you can enter an IP address like 8.8.8.8, since this will be overridden by the Gateway’s gateway’s configuration.

Anchor
linklock
linklock
(ENGAGE) Link the

...

lock to the

...

gateway:

  1. Tap on the gateway from the list of devices.

  2. Tap Linked Devices.

  3. Tap on the plus sign to link a lock.

  4. Tap on the name of the lock to link it to the Gatewaygateway.

Info

Note: You may need to refresh this page or turn the lock handle to make the lock appear on this list. Also, make sure the cover is secured on the lock.

5. Back out of the app so you're no longer connected to the Gatewaygateway.

Anchor
sync
sync
(Open Admin) Sync

...

gateways and

...

locks to Avigilon Alta:

  1. Open the Open Admin Alta Access app.

  2. Tap the name of the Org org to which you’ll provision these locks and gateways.

  3. Tap 3rd Party Devices.

  4. Tap Allegion Wireless Gateways (Schlage).

  5. Tap Sync Gateways.

  6. Review the list of gateways and locks.

Anchor
update
update
Update firmware on the

...

gateways and locks:

  1. Go to https://control.openpath.com/login and log in. To access the European Alta Access, please go to https://control.eu.openpath.com/login.

  2. Go to Devices > Wireless Gateway.

    1. Under the Actions column, click Update Firmware next to each Gateway.

  3. Go to Devices > Wireless Locks.

    1. From this page, select locks and click Batch Actions to update the firmware.

Info

Note: To downgrade Allegion Lock lock and Gateway gateway firmware follow these steps.

Anchor
locksettings
locksettings
Adjust lock settings in Alta Access:

Info

Note: Settings are dependent on the lock model and configuration. To configure the following wireless lock function, set it during the commissioning process or post-installation using the Schlage ENGAGE mobile app (and not Alta Access):

  • Apartment mode - Supported in LEB and NDEB series locks only. Ensures the gateway-connected or No-tour connected lock remains open or closed, when the credential is scanned. The door doesn't automatically relock when unlocked, and thus, lock out the user.

    Confirm the 'Openpath does not support Toggle Credential' message during initial configuration. For more information, see the Schlage ENGAGE documentation.

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/images/kustomer-articles/lock-management.png
width700
frameborderhide
alignmiddle
titleLock Management
longdescLock Management
height268

To configure an NDEB or LEB lock:
  1. Go to https://control.openpath.com/login and log in. To access the European Alta Access, please go to https://control.eu.openpath.com/login.

  2. Go to Devices > Wireless Locks.

  3. Click on the name of the lock to edit it.

  4. Under Basic Settings, you can do the following:

    1. From the Power Failure dropdown, select how the lock will behave in the event of the battery failing.

      1. As Is – the lock will remain in the same state.

      2. Safe – unlocked.

      3. Secure – locked.

    2. Enable or disable the Beeper on the lock when a credential is scanned.

    3. Adjust the interior LED settings.

    4. Enable or disable the Invalid Card Audit, which logs invalid credentials.

  5. Under Reader Settings, choose which type of card and fob credentials may be used at this lock.

    1. For Openpath DESFire EV1, EV2, and EV3 enable 14443 UID (CSN).

    2. For Openpath DESFire EV3-A, select 14443 EV1 (NOC).

...

  1. Under Mobile Credential, choose whether to enable mobile credentials on this lock.

    1. Adjust the Communication Range to determine how close the mobile credential needs to be to the lock before appearing as a nearby entrYou . You cannot enable 14443 UID (CSN) and 14443 Secure Mifare/Mifare Plus/EV1 (NOC) at the same time .y in the app.

    2. Adjust Performance to determine how often the mobile app scans for locks.

  2. Click Save.

Iframe
srchttps://info.openpath.com/hubfs/images/kustomer-articles/edit-lock.png
width700
frameborderhide
titleEdit Lock
alignmiddle
height293
longdescEdit lock

To configure a Control lock:
  1. From Wireless Locks, click on the name of the lock to edit it.

  2. Under Basic Settings, you can do the following:

    1. Enable or disable the Beeper on the lock when a credential is scanned.

    2. Enable or disable the Invalid Card Audit, which logs invalid credentials.

  3. Reader Settings cannot be edited on Control locks; high-frequency cards and fobs are enabled by default.

  4. Under Mobile Credential, choose whether to enable mobile credentials on this lock.

    1. Adjust the Communication Range to determine how close the mobile credential needs to be to the lock before appearing as a nearby entry in the app.

    2. Adjust Performance to determine how often the mobile app scans for locks.

  5. Click Save.

Anchor
create-entry
create-entry
Create an

...

entry in Alta Access:

Once you’ve set up and commissioned your Allegion wireless locks, you can create entries with them similar to how you would with Avigilon Readersreaders.

Anchor
movegateway
movegateway
How to add a

...

gateway from another

...

organization

If you need to move a Gateway gateway from one org to another, you will need to use the ENGAGE app to remove it from the original org and then Sync sync against Allegion using the Alta Access app, Step 7, or from the Wireless Lock Gateway Management page in Alta Access. Once you do that you can add the Gateway gateway to the new org using the ENGAGE app, Step 4.

...