You can set up the Single Door Controller (SDC) using the Open Alta Admin app. Open Admin The app lets you provision and troubleshoot SDCs using your mobile device. For more information, refer to How do I to use the Open Admin Alta Access app?

For iOS devices: Download on the App Store

For Android devices: Download on the Google Play Store

Info

Note: Before you can provision an SDC using the

...

Alta Access app, you must first create an ACU in the

...

Alta Access system. See How

...

to create ACUs in

...

Avigilon Alta Access

...

Single Door Controller Admin button

...

:

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/images/kustomer-articles/sdc-admin-button.png

...

width500
frameborderhide
alignmiddle
titleAdmin Button
longdescSDC Admin Button setup
height483

Setting up the SDC

...

:

  1. If powering using PoE, plug in Ethernet; if powering with an external power supply, plug in Ethernet and connect power to POWER IN. The Status LED will be solid cyan.

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/images/kustomer-articles/sdc-solid-cyan.png

...

width90
frameborderhide
aligntop
titleCyan
longdescSDC Solic Cyan
height90

2. In the Alta Access app, locate the org to which you're provisioning hardware, either on the list or using search, then tap on the org name.

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/images/kustomer-articles/sdc-solid-

...

cyan.png
width90
frameborderhide
alignmiddle
titleCyan
longdescSDC Setup Cyan
height90

3. Wait until the Status LED is solid blue, then press the Admin button (see above) on the SDC.

Info

Note: SDC will disconnect from the Alta Access app after 5 minutes of inactivity; press the Admin button again to reset the timer.

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/images/kustomer-articles/sdc-

...

solid-

...

blue.png
width90
frameborderhide
alignmiddle
titlesolid blue
longdescadmin press solid blue
height90

4. When the Status LED is blinking purple, in the app, tap on the last four digits of the serial number for the SDC.

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/images/kustomer-articles/sdc-

...

blinking-purple.png

...

width90
frameborderhide
alignmiddle
titleblinking purple
longdescadmin button blinking purple
height90

5. When the Status LED changes to solid purple, tap Test Internet Connection and wait for a green YES to appear before proceeding with the next step.

Info

Note: This checks if the ACU/SDC can ping https://api.openpath.com/health

](https://api.openpath.com/health) If this step fails, refer to [Troubleshooting the SDC](https://openpath.atlassian.net/servicedesk/customer/portal/16/article/760217849?src=-1563331011#troubleshoot). | | ![solid purple](

. See Troubleshooting the SDC

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/images/kustomer-articles/sdc-solid-purple.png

...

width90
frameborderhide
alignmiddle
titlesolid purple
longdescsolid purple
height90

6. If the Internet connection test is successful, tap Provision Device in the app.

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/images/kustomer-articles/sdc-solid-purple.png

...

width90
frameborderhide
alignmiddle
titleprovision device
longdescprovision device
height90

7. Tap on the ACU Name that you want to provision to (this is the name of the SDC you created in Avigilon Alta Access), then tap Yes to proceed.

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/images/kustomer-articles/sdc-solid-

...

purple.png
width90
frameborderhide
alignmiddle
titleproceed to provision
longdescproceed to provision
height90

8. The Status LED will blink yellow; the app will send notifications when the SDC provision state changes from Unprovisioned to Provisioning in progress to Provisioning complete.

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/images/kustomer-articles/sdc-solid-

...

yellow.png
width90
frameborderhide
alignmiddle
titleblink yellow
longdescblink yellow
height90

9. When setup is complete, the Status LED will change to solid white.

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/images/kustomer-articles/sdc-

...

solid-

...

white.png
width90
frameborderhide
alignmiddle
titlesolid white
longdescsolid white
height90


Anchor
troubleshoot
troubleshoot
Troubleshooting the SDC

If at any point the Status LED blinks red, this indicates there is an issue connecting to the Internet. If attempting to set up using Wi-Fi, try switching to an Ethernet connection. Refer to What are the Network Requirements for Avigilon Controllers?

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/images/kustomer-articles/sdc-

...

blinking-red.png

...

width90
frameborderhide
alignmiddle
titleBlinking red
longdescBlinking red
height90

If at any point the Status LED is solid red, this indicates the SDC is in an error state. Go to the Hardware Dashboard in Alta Access and restart the services listed under Remote Diagnostics. If this doesn't work, power cycle the SDC (remove power, wait 10 seconds, and apply power). If the error persists, contact Avigilon Alta support.