Nedap uPASS Reach readers use UHF RFID technology and . They are often used for long-range vehicle identification in parking garages.

Info

Note: This reader requires external power. Current consumption: 1A @ 12VDC or 500mA @ 24VDC. For more information, refer to the uPASS Reach user guide.

Integrating uPASS Reach readers with Core Series hardware

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/images/kustomer-articles/nedap-4port.png
width700
frameborderhide
titlenedap
alignmiddle
height630
longdescNadap uPASS

Wiring uPASS Reach reader with Core Series hardware

Nedapp uPASS Reach

Openpath

Avigilon Alta Core Series hardware

OUT2 (D0)

AUX1 (D0)

OUT3 (D1)

AUX2 (D1)

GND

GND

Integrating uPASS Reach readers with first-generation hardware

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/images/kustomer-articles/controller-board-upass.png
width700
frameborderhide
titleuPASS controller board
alignmiddle
height875
longdescuPASS First-Gen controller board

Wiring uPASS Reach reader with first gen hardware

Nedapp uPASS Reach

Openpath

Avigilon Alta first gen hardware

OUT2 (D0)

D0

OUT3 (D1)

D1

GND

GND

Integrating uPASS Reach readers with Single Door Controller

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/images/kustomer-articles/sdc-upass.png
width700
frameborderhide
titleSDC uPASS
alignmiddle
height755
longdescSDC uPASS

Wiring uPASS Reach reader with Single Door Controller (SDC)

Nedapp uPASS Reach

Openpath

Avigilon Alta SDC

OUT2 (D0)

D0

OUT3 (D1)

D1

GND

GND

Setting up uPASS Reach reader in

...

Alta Access

To configure Wiegand inputs on Core Series hardware:

  1. Go to https://control.openpath.com/login and log in. To access the European Control CenterAlta Access, please go to https://control.eu.openpath.com/login.

  2. Go to Devices > ACUs, then click on the ACU to edit it.

  3. Click on the Ports tab.

  4. Click Port next to the first input of the I/O pair with the uPASS Reach reader configured.

  5. Select Wiegand Device from the Input Type dropdown, then click Save.

This will label the subsequent input as Wiegand Device (Extended) and disable it from editing. Inputs cannot be changed if they are already assigned to an entry.

...

Input settings in the Control CenterAlta Access

Once the Wiegand Device is configured on the ACU, it can be assigned to an entry. 

...

For more information on creating Entries, refer to the Openpath Avigilon Alta User Guide.

To add a uPASS Reach reader to an entry:

  1. Go to https://control.openpath.com/login and log in. To access the European Control CenterAlta Access, please go to https://control.eu.openpath.com/login.

  2. Go to Sites > Entries and click on an existing entry to edit or click the plus(+) on the top right to Create an Entry.

  3. Scroll down to Wiegand Device.

  4. From the Port dropdown, select the port for the uPASS Reach reader to which this entry is wired.

  5. From the Mode dropdown, select Input.

  6. Click Save.