Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Go to Configurations > Rule Engine

  2. Click Create Rule

  3. Enter a name and description for the rule

  4. In the Trigger section:

    1. From the Type dropdown select Input 

    2. From the Event dropdown select Generic Input State Changed

      rule1-info-trigger.pngImage Removedrule1-info-trigger.pngImage Added
  5. In the Conditions section:

    1. Click Add Condition

    2. From the Type dropdown, select Input State

    3. In the State to Match dropdown select high

    4. Click Add Condition again

    5. From the Type dropdown, select ACU Port Filter

    6. From the ACU To Match dropdown, select the ACU with Door A

    7. From the ACU Port To Match dropdown, select Door A's Generic Input

      rule1-conditions-small.pngImage Removedrule1-conditions-small.pngImage Added
  6. In the Actions section:

    1. From the Type dropdown select Lockdown

    2. From the Lockdown Plan dropdown, select the plan you created for Door A and Door B

    3. From the Lockdown Action dropdown, select Trigger Lockdown

      rule1-trigger-lockdown-a-b.pngImage Removedrule1-trigger-lockdown-a-b.pngImage Added
  7. Click Save

To create Rule 2, repeat the steps for Rule 1 but change the following:

...