Go to https://control.openpath.com/login and log in. To access the European Alta Access, please go to https://control.eu.openpath.com/login.
Go to Devices > ACUs.
Click the ACU that contains door A, then click the Ports tab.
Select a contact or REX input that is unused by an entry and change it to a Generic Input.
Note: This input must physically connect to a contact sensor on door A.
Repeat these steps to create a generic input on the ACU that contains door B (this may be the same ACU).
It is still required to have inputs set up for contact sensors To ensure proper functionality, contact sensors must be configured for each entry for point of doors A and B on top of , in addition to the generic inputs. Wires that connect to generic inputs for mantrap setup need to be parallel wired to For the mantrap setup, the wires connecting to the generic inputs must be connected in parallel with the contact sensors.
Second, create a Lockdown Plan:
...