A mantrap is an access control configuration that consists of interlocking doors, commonly used in banks, airports, and other high-security areas. In this setup, Door door A must close before Door door B can open, and Door door B must close before Door door A can open.
Info |
---|
Note: To set up a mantrap configuration in Avigilon Alta, you'll need to create a Lockdown plan and a handful of rules available with the basic Rules Engine. |
...
Go to https://control.openpath.com/login and log in. To access the European Control CenterAlta Access, please go to https://control.eu.openpath.com/login.
Go to Devices > ACUs.
Click the ACU that contains Door door A, then click the Ports tab.
Select a Contact or REX input that is unused by an entry and change it to a Generic Input.
Note: This input must physically connect to a contact sensor on Door door A.
Repeat these steps to create a Generic Input on the ACU that contains Door door B (this may be the same ACU).
...
Go to Sites > Lockdown Plans.
Click Create Lockdown Plan.
Select the Zone(s) to be used in the mantrap (Door door A and Door door B).
Set the Triggered State to Locked - no entry.
Click Save.
...
Rule 1 - Door A in High State triggers the Lockdown Plan associated with Door A and Door B.
Rule 2 - Door A in Low State reverts the Lockdown Plan associated with Door A and Door B.
Rule 3 - Door B in High State triggers the Lockdown Plan associated with Door A and Door B.
Rule 4 - Door B in Low State reverts the Lockdown Plan associated with Door A and Door B.
...