To enable this feature, refer to How to enable features in Avigilon Alta Access.

Requirements

Info

Note: The org’s Site in Alta Access must have an address in order to get accurate timestamps on Allegion events. Go to Sites > Site > Edit Site to enter an address.

Overview of setup

Note: You must perform these steps in the specified order.

  1. Install Gateways and locks (refer to Allegion documentation)

    1. Schlage LE Lock Installation Guide

    2. Schlage NDE Lock Installation Guide

    3. Schlage Control Deadbolt Installation Guide

    4. Schlage Control Interconnected Installation Guide

    5. Engage Gateway Installation Guide

  2. Present Configuration Card to the lock

  3. Accept the invitation to Allegion Site

  4. Add the Gateway in the ENGAGE app

  5. Add the lock in the ENGAGE app

  6. Link the lock to the Gateway

  7. Sync gateways and locks to Avigilon Alta

  8. Update firmware on gateways and locks

  9. Adjust lock settings in Avigilon Alta Access

  10. Create an entry with the wireless lock

  11. How to add a Gateway from another Org

Anchor
present
present
Present Configuration Card to lock:

If you purchased locks outside of Avigilon Alta, and you’re using Openpath DESFire card credentials, present the appropriate Configuration Card to the lock within the first minute of powering on. A triple beep followed by a full reader reset indicates success.

Anchor
accept
accept
(Open Admin) Accept the invitation to the Allegion Site:

  1. Open the Open Admin app first.

  2. Tap the name of the Org to which you’ll provision these locks and gateways.

  3. Tap 3rd Party Devices.

...

  1. On the web page, accept Allegion’s terms and create an account using the email address associated with your Avigilon Alta account.

Anchor
addgateway
addgateway
(ENGAGE) Add the Gateway:

  1. Open the ENGAGE app and log in.

  2. Tap on the plus sign to add a device.

  3. Tap on Gateway.

  4. Tap the gateway’s serial number.

  5. Enter a name for the gateway.

  6. For Gateway communication mode, tap IP.

  7. On IP Configuration, enable IP Behind Firewall and tap DHCP.

  8. On the IP Behind Firewall screen, enter the following:

    Code Block
    Server URL: https://ozone.prod.openpath.com 
    CA Server URL: http://ozone.prod.openpath.com/cert
Info

Note: These URLs must be entered correctly in order for the integration to work. If you entered them incorrectly during setup, you can edit them later by tapping on the Gateway > Settings > Host Configuration.

Anchor
addlock
addlock
(ENGAGE) Add the Lock:

  1. Tap on the plus sign to add a device.

  2. Tap on the model of lock you’re commissioning (Avigilon Alta supports LEB, NDEB, and Control locks).

  3. The app will ask if you want to use default settings — tap Yes (you can adjust lock configurations later in the Avigilon Alta Access).

  4. Tap the lock’s serial number.

  5. Follow the in-app instructions for connecting the lock.

  6. Enter a name for the lock.

  7. (NDEB and LEB only) On the Select the lock function page, select Storeroom.

...

8. Skip the Wi-Fi configuration step if able, since the lock will connect to the Internet via the Gateway. Some lock models might require that you specify a Wi-Fi configuration, in which case, you can enter an IP address like 8.8.8.8, since this will be overridden by the Gateway’s configuration.

Anchor
linklock
linklock
(ENGAGE) Link the Lock to the Gateway:

  1. Tap on the gateway from the list of devices.

  2. Tap Linked Devices.

  3. Tap on the plus sign to link a lock.

  4. Tap on the name of the lock to link it to the Gateway.

...

5. Back out of the app so you're no longer connected to the Gateway.

Anchor
sync
sync
(Open Admin) Sync Gateways and Locks to Avigilon Alta:

  1. Open the Open Admin app.

  2. Tap the name of the Org to which you’ll provision these locks and gateways.

  3. Tap 3rd Party Devices.

  4. Tap Allegion Wireless Gateways (Schlage).

  5. Tap Sync Gateways.

  6. Review the list of gateways and locks.

Anchor
update
update
Update firmware on the Gateways and locks:

  1. Go to https://control.openpath.com/login and log in. To access the European Alta Access, please go to https://control.eu.openpath.com/login.

  2. Go to Devices > Wireless Gateway.

    1. Under the Actions column, click Update Firmware next to each Gateway.

  3. Go to Devices > Wireless Locks.

    1. From this page, select locks and click Batch Actions to update the firmware.

Info

Note: To downgrade Allegion Lock and Gateway firmware follow these steps.

Anchor
locksettings
locksettings
Adjust lock settings in Alta Access:

Info

Note: Settings are dependent on the lock model and configuration. To configure the following wireless lock function, set it during the commissioning process or post-installation using the Schlage ENGAGE mobile app (and not Alta Access):

  • Apartment mode - Supported in LEB and NDEB series locks only. Ensures the gateway-connected or No-tour connected lock remains open or closed, when the credential is scanned. The door doesn't automatically relock when unlocked, and thus, lock out the user.

    Confirm the 'Openpath does not support Toggle Credential' message during initial configuration. For more information, see the Schlage ENGAGE documentation.

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/images/kustomer-articles/lock-management.png
width700
frameborderhide
alignmiddle
titleLock Management
longdescLock Management
height268
To configure an NDEB or LEB lock:
  1. Go to https://control.openpath.com/login and log in. To access the European Alta Access, please go to https://control.eu.openpath.com/login.

  2. Go to Devices > Wireless Locks.

  3. Click on the name of the lock to edit it.

  4. Under Basic Settings, you can do the following:

    1. From the Power Failure dropdown, select how the lock will behave in the event of the battery failing.

      1. As Is – the lock will remain in the same state.

      2. Safe – unlocked.

      3. Secure – locked.

    2. Enable or disable the Beeper on the lock when a credential is scanned.

    3. Adjust the interior LED settings.

    4. Enable or disable the Invalid Card Audit, which logs invalid credentials.

  5. Under Reader Settings, choose which type of card and fob credentials may be used at this lock.

    1. For Openpath DESFire EV1, EV2, and EV3 enable 14443 UID (CSN).

    2. For Openpath DESFire EV3-A, select 14443 EV1 (NOC).

...

Iframe
srchttps://info.openpath.com/hubfs/images/kustomer-articles/edit-lock.png
width700
frameborderhide
titleEdit Lock
alignmiddle
height293
longdescEdit lock
To configure a Control lock:
  1. From Wireless Locks, click on the name of the lock to edit it.

  2. Under Basic Settings, you can do the following:

    1. Enable or disable the Beeper on the lock when a credential is scanned.

    2. Enable or disable the Invalid Card Audit, which logs invalid credentials.

  3. Reader Settings cannot be edited on Control locks; high-frequency cards and fobs are enabled by default.

  4. Under Mobile Credential, choose whether to enable mobile credentials on this lock.

    1. Adjust the Communication Range to determine how close the mobile credential needs to be to the lock before appearing as a nearby entry in the app.

    2. Adjust Performance to determine how often the mobile app scans for locks.

  5. Click Save.

Anchor
create-entry
create-entry
Create an Entry in Alta Access:

Once you’ve set up and commissioned your Allegion wireless locks, you can create entries with them similar to how you would with Avigilon Readers.

Anchor
movegateway
movegateway
How to add a Gateway from another Org

If you need to move a Gateway from one org to another, you will need to use the ENGAGE app to remove it from the original org and then Sync against Allegion using the Alta Access app, Step 7, or from the Wireless Lock Gateway Management page in Alta Access. Once you do that you can add the Gateway to the new org using the ENGAGE app, Step 4.

...