Configuring the Input in Alta Access (Not Required for Auxiliary Input)

  1. Access Alta Access:

  2. Edit the ACU:

    • Navigate to Devices > ACUs.

    • Click on the ACU you want to edit.

  3. Configure the Port:

    • Go to the Ports tab.

    • Click on the port next to the input wired to the button (e.g., Contact4).

    • Select Generic Input from the Input Type dropdown, then click Save.

Creating a Lockdown Plan

  1. Refer to Instructions:

Creating Rules in the Rules Engine

  1. Access the Rules Engine:

    • Go to Configurations > Rules.

    • Click the plus (+) sign in the top right corner to create a new rule.

  2. Define the Rule:

    • Enter a name and description for the rule.

  3. Set the Trigger:

    • In the Trigger section:

      • From the Type dropdown, select Input.

      • From the Event dropdown, select Generic Input State Changed.

  4. Add Conditions:

    • In the Conditions section:

      • Click Add Condition.

        • From the Type dropdown, select ACU Port Filter.

        • From the ACU To Match dropdown, select the ACU with the wired button.

        • From the ACU Port To Match dropdown, select the button's Generic Input (e.g., Contact4).

      • Click Add Condition again.

        • From the Type dropdown, select Input State.

        • From the State to Match dropdown, select the appropriate state (based on how the button is wired).

          • For toggle switch buttons wired to NC, select high to trigger and low to revert.

          • For toggle switch buttons wired to NO, select low to trigger and high to revert.

  5. Define Actions:

    • In the Actions section:

      • From the Type dropdown, select Lockdown.

      • From the Lockdown Plan dropdown, select the plan you want the button to trigger.

      • From the Lockdown Action dropdown, select Trigger Lockdown.

    • Repeat steps 1-5. In step 5, under the Lockdown Action dropdown, select Revert Lockdown.

  6. Save the Rule:

    • Click Save.