You can configure Avigilon Alta to disarm security alarms through physical wiring (explained below) or through API webhooks with the Rules Engine.
To physically wire Avigilon Alta to a security alarm system, contact the alarm company and ask them to program a “keyswitch” on the alarm panel that can connect to the Openpath ACU. The dry relay should disable the alarm system.
Once configured, the Avigilon Alta integrator can connect the alarm panel's “keyswitch” to a dry relay on the Openpath ACU.
To configure the dry relay in the Control Center:
Go to https://control.openpath.com/login and log in. To access the European Control Center, please go to https://control.eu.openpath.com/login
Go to Sites > Entries and click on the Entry that is wired to the alarm
Scroll down to Additional Controls, select Entry/Exit Hardware, then click Add Control
Scroll up to Entry/Exit Hardware and configure accordingly
At the bottom of the page, click Save
When a user opens the entry, the alarm will disarm
Note: You can add additional Openpath Readers to the alarm system relay by adding them to this entry using Add Control, but this will result in duplicate logs when the entry is unlocked.