Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

There are two ways to install the Standard Keypad Reader; flush mounted on a single gang box or surface mounted using the provided backplate. The Mullion Keypad Reader can only be surface mounted. It is perfect when space is limited, such as a door frame.

Mounting Instructions

...

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/Openpath/images/kustomer-articles/flush_mount.png

...

width522
frameborderhide
alignmiddle
titleflush mount
longdescflush mount Openpath keypad
height309

Standard Keypad Reader Installation - Flush Mount

  1. Install a recessed single gang box (D) into the wall.

  2. Strip and connect the wires.

  3. Use the #6-32 screws (B) to attach the reader (C) to the wall. Do not use the provided back plate for flush mount installations.

  4. Snap-on the front cover (A). Do not use adhesive.

...

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/Openpath/images/kustomer-articles/surface_mount.png

...

width514
frameborderhide
alignmiddle
titlesurface mount
longdescsurface mount Openpath Keypad
height248

Standard Keypad Reader Installation - Surface Mount

...

  1. Attach the back plate to the wall.

    1. On drywall: use wall anchors and appropriate screws.

    2. On a UK single gang box: use four machine screws (not included).

    3. On a German single gang box: use two machine screws (not included) on the top and bottom holes.

  2. Strip and connect the wires.

  3. Use the #8-32 screws (B) to attach the reader (C) to the back plate.

  4. Snap-on the front cover (A). Do not use adhesive.

...


Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/Openpath/images/kustomer-articles/mullion_keypad.png

...

width293
frameborderhide
alignmiddle
titlemullion mount
longdescMullion Mount Openpath Keypad
height259

Mullion Keypad Reader Installation

  1. Strip and connect the wires.

  2. If installing on a metal surface, drill and tap to use the provided machine screws (B). Or, use self-tapping screws.

  3. Attach the reader (G) to the wall.

  4. Snap-on the front cover (F). Do not use adhesive.

Wiring Information

...

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/Openpath/images/kustomer-articles/wiring_keypad.png

...

width568
frameborderhide
alignmiddle
titlewiring keypad
longdescWiring Openpath Keypad
height321

After installing the Avigilon Keypad Reader, check out the How to Program the Avigilon Keypad Reader in the Control CenterAvigilon Alta Access guide to complete the installation.

Related Articles:

How to create an entry for the Openpath Avigilon Keypad Reader

Avigilon Keypad Reader FAQs