Removing the lock from the gateway doesn't update in the Control CenterAlta Access
Not enough licenses for non-Avigilon Alta-sourced locks
Directions for turning on Allegion for legacy subscription accounts
...
Info |
---|
Note: We recommend trying the steps in the sequence they are listed |
Troubleshooting
Issue
Anchor | ||||
---|---|---|---|---|
|
...
Check that the mobile app is on the latest version
Check error codes received from the mobile app
Verify the number of users with access to the lock, ensuring it does not exceed the maximum user capacity supported by the Allegion lock. (Refer to the Allegion specification sheets to confirm the maximum capacity for your lock model.)
Check the BLE reader "Communication Range" (should be long) and "Performance" (should be max). This is changed/set in the Allegion ENGAGE app
Check if valid card reads work
Run "Identify" on the Wireless Lock Devices page in the Control Center Alta Access (If it is a gateway-connected device)
Run activity report with entry filter to see if lock/gateway has reported errors (Example: “Offline”)
Check for "Doorfile Updated Successfully" message in the activity logs report (If it is a gateway-connected device) to ensure that the lock has successfully processed the last access update
Use the Send feedback on the Avigilon Alta Open mobile app
...
Check user access through the User Access Audit report in the Control Center ReportsAlta Access Reports
Verify the number of users with access to the lock, ensuring it does not exceed the maximum user capacity supported by the Allegion lock. (Refer to the Allegion specification sheets to confirm the maximum capacity for your lock model.)
If the card is no-tour, verify that if the Schlage fob is being used it was purchased from Avigilon Alta
(Schlage cards/fobs not purchased from Avigilon are not supported)Power cycle the gateway
Power cycle lock
Remove/reattach network cable for gateway
Test network cable for the gateway on a laptop to ensure internet connectivity
Try another cable
Try another port
Run "Identify" on the Wireless Lock Devices page (If it is a gateway-connected device)
Hold card to reader for 5+ seconds to ensure all data is read for initial unlock
Run activity report with entry filter to see if lock/gateway has reported errors
Check for "Doorfile Updated Successfully" message in the activity logs report (If it is a gateway-connected device)
Is the gateway powered via PoE? Try an AC adapter
...
Anchor | ||||
---|---|---|---|---|
|
Troubleshooting steps
Click the "Sync Devices" button on the wireless locks/wireless gateways page in the Control CenterAlta Access
Power cycle gateway
Remove/reattach network cable for gateway
...
Anchor | ||||
---|---|---|---|---|
|
Troubleshooting steps
Remove/reattach network cable for gateway
Is the gateway powered via PoE? Try an AC adapter
...
From the Partner Dashboard in the Control CenterAlta Access
Go to Manage organizations
Click on the organization you would like to add Allegion to
From the Edit organization page click “Subscriptions” at the top
From your selected plan, scroll down and toggle the tile labeled “Allegion Wireless Locks Purchased from Openpath” then click save at the bottom of the page
...
There is a hard limit. If you need a credential with access to more than 11 wireless lock entries, you need to mark the credential as non-no-tour and then tour the locks with the Admin App. Mobile no-nour has no limit.
...
Anchor | ||||
---|---|---|---|---|
|
If you upgraded via the ENGAGE app, their versions are newer than what is approved and tested by Avigilon Alta. Please reach out to Support.
...
Model | Approved Versions |
---|---|
GWE | 01.6465.04 |
Wireless Locks
Model | Approved Versions |
---|---|
LEB (all variations) | 03.10.01 03.11.02 03.14.02 |
NDEB | 03.10.01 03.11.02 03.14.02 |
FE410B | 04.1012.0100 04.1214.0001 |
BE467B | 04.1012.0100 04.1214.0001 |
FE410BM | 05.11.39 05.13.01 |
BE467BM | 05.11.39 05.13.01 |