Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

To integrate your intercom system (Not the Avigilon Alta Video Intercom Reader Pro) with Avigilon Alta, connect a dry contact relay from each intercom to a REX input on the Avigilon Alta ACU. Twisted pair wiring is recommended.

Additionally, you can wire a REX sensor in parallel with the intercom (figures 1 and 2) or directly to your locking hardware (figures 3 and 4), depending on the door location and building code requirements. 

Option 1: Wiring REX in parallel with the intercom

Figure 1: Wiring intercom with optional in-parallel REX to 4-Port Board.

Iframe
srchttps://info.openpath.com/hubfs/images/kustomer-articles/intercom-in-parallel-REX-core.png
width700
frameborderhide
titlewiring intercom
alignmiddle
height474
longdescWiring intercom with optional in-parallel REX to 4-Port Board

Figure 2: Wiring intercom with optional in-parallel REX to 4-Door Controller.

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/images/kustomer-articles/intercom-in-parallel-REX-4door.png
width700
frameborderhide
alignmiddle
titleWiring intercom
longdescWiring intercom with optional in-parallel REX to 4-Door Controller
height554

Option 2: Wiring REX to locking hardware

Figure 3: Wiring intercom with optional REX to mag lock on 4-Port Board.

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/images/kustomer-articles/intercom-REX-lock-core.png
width700
frameborderhide
alignmiddle
titleintercom-REX-lock-core
longdescWiring intercom with optional REX to mag lock on 4-Port Board
height395

Figure 4: Wiring intercom with optional REX to mag lock on 4-Door Controller.

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/images/kustomer-articles/intercom-REX-lock-4door.png
width700
frameborderhide
alignmiddle
titleintercom-REX-lock-4door
longdescWiring intercom with optional REX to mag lock on 4-Door Controller
height547

Note on using the intercom for access:

  • If you plan on using the intercom’s card reader for access (without an Avigilon Alta Smart Reader), run the W0, W1, and GND signals from the intercom to a Wiegand input on the 4-Door Controller or any I/O pair on the 4-Port, 8-Port, or 16 I/O Elevator Board. The intercom power supply and the ACU power supply should share a common ground. See How to wire Wiegand devices to Core Series hardware.

  • If you are installing an Avigilon Alta Smart Reader at the same entry as the intercom, connect the Wiegand W0 and W1 signals from the intercom directly to the WD0 (Green) and WD1 (White) wires on the Smart Reader pigtail.

  • The REX signal can also pass back to the ACU in the same cable bundle as the Smart Reader wires if there is a spare twisted pair available. Run power for the intercom separately, since it may require heavier gauge wires.

Additional resources

Learn more about Avigilon Alta integrations