You can configure Anti-Passback to use in and out (entry and exit) readers by configuring two entries with two Openpath Avigilon readers and two relays sharing one lock.

...

Iframe
allowfullscreentrue
srchttps://info.openpath.com/hubfs/Openpath/images/kustomer-articles/op-4ex4-wiring-diagram-apb-same-lock

...

_proper.png
width700
frameborderhide
titleanti passback same lock
alignmiddle
height435
longdescanti passback same lock

To configure the hardware:

  1. Install two Openpath Avigilon readers, one on either side of the door (or turnstile, parking gate, etc.)

  2. Connect the readers and lock to the Openpath Avigilon ACU

  3. In this example, the following are connected to the 4-Port Board:

    1. The in/entry Openpath Avigilon Reader is connected to READER 1

    2. The out/exit Openpath Avigilon Reader is connected to READER 3

    3. The lock is connected to RELAY 1

    4. RELAY 3 is connected to REX 1 (which will trigger RELAY 1)

To configure the entries in the Control CenterAvigilon Alta Access:

  1. Go to https://control.openpath.com/login and log in. To access the European Partner CenterAlta Access, please go to https://control.eu.openpath.com/login

  2. Go to Sites > Entries and create two entries (billing charges may apply)

    1. Click the plus(+) sign in the top right corner to Create an Entry

    2. Give the entry a name, assign a zone, and select the Controller you just configured

    3. Under Entry/Exit Hardware, select Relay 1

    4. Under Openpath Avigilon Reader, select Reader 1

    5. Click Save

    6. Repeat these steps for the Out Reader, selecting Relay 3 and Reader 3