Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Single Door Controller Admin button

Setting up the SDC

Image Modified

(1) If powering using PoE, plug in Ethernet; if powering with an external power supply, plug in Ethernet and connect power to POWER IN

The Status LED will be solid cyan

Image Modified

(2) In the Open Admin app, locate the org to which you’re provisioning hardware, either on the list or using search, then tap on the org name

Image Modified

(3) Wait until the Status LED is solid blue, then press the Admin button (see above) on the SDC

Note: SDC will disconnect from the Open Admin app after 5 minutes of inactivity; press the Admin button again to reset the timer

Image Modified

(4) When the Status LED is blinking purple, in the app, tap on the last four digits of the serial number for the SDC

Image Modified

(5) When the Status LED changes to solid purple, tap Test Internet Connection and wait for a green YES to appear before proceeding with the next step

Note: This checks if the ACU/SDC can ping https://api.openpath.com/health

If this step fails, refer to Troubleshooting the SDC

Image Modified

(6) If the Internet connection test is successful, tap Provision Device in the app

Image Modified

(7) Tap on the ACU Name that you want to provision to (this is the name of the SDC you created in the Control Center), then tap Yes to proceed

blinking-yellow.pngImage RemovedImage Added

(8) The Status LED will blink yellow; the app will send notifications when the SDC provision state changes from Unprovisioned to Provisioning in progress to Provisioning complete

Image Modified

(9) When setup is complete, the Status LED will change to solid white


Anchor
troubleshoot
troubleshoot
Troubleshooting the SDC

Image Modified

(1) If at any point the Status LED blinks red, this indicates there is an issue connecting to the Internet. If attempting to set up using Wi-Fi, try switching to an Ethernet connection. 

Refer to What are the Network Requirements for Openpath Controllers?

solid-red.pngImage RemovedImage Added

(2) If at any point the Status LED is solid red, this indicates the SDC is in an error state. Go to the Hardware Dashboard in the Control Center and restart the services listed under Remote Diagnostics. If this doesn’t work, power cycle the SDC (remove power, wait 10 seconds, apply power). If the error persists, contact Openpath support.