SOFT RESET

To soft reset the ACU, disconnect power from the ACU, wait 10 seconds, then reconnect the power. 

HARD RESET

WARNING: Only hard reset the ACU if absolutely necessary and if instructed by Openpath. This will clear all of the data off of the ACU and will require reprovisioning with the Admin app or with a laptop.

To hard reset the ACU:

  1. Disconnect power from the ACU

  2. Hold down the ADMIN BUTTON for 15 seconds

  3. While still holding down the ADMIN button, reconnect the power, and continue to hold the button for another 15 seconds. If resetting a 4 Door Controller, you should see two POWER LEDs light up in the top left corner.

  4. Wait 15 minutes before provisioning the ACU

Image RemovedImage Added

ADMIN button on 4 Door Controller

Image RemovedImage Added

ADMIN button on Core Board