You can configure Anti-Passback to use in and out (entry and exit) readers by configuring two entries with two Openpath Avigilon readers and two relays sharing one lock.

...

To configure the hardware:

  1. Install two Openpath Avigilon readers, one on either side of the door (or turnstile, parking gate, etc.)

  2. Connect the readers and lock to the Openpath ACU

  3. In this example, the following are connected to the 4-Port Board:

    1. The in/entry Openpath Avigilon Reader is connected to READER 1

    2. The out/exit Openpath Avigilon Reader is connected to READER 3

    3. The lock is connected to RELAY 1

    4. RELAY 3 is connected to REX 1 (which will trigger RELAY 1)

...